KYTC currently uses Midwest Guardrail System (MGS) for new installations of standard guardrail and corresponding end treatments. MGS is a non-proprietary steel or wood post W-beam guardrail system that meets MASH Test Level 3 criteria. The system adopts a typical W-beam guardrail with the following characteristics:
Click here to get more.
• 31-inch top of rail mounting height and tolerance of +/- 1 inch (see Section 3.5, Guardrail Height).
• Minimum 6-foot-long W6 x 9 steel posts or 6-inch x 8-inch wood posts
o Longer posts may be used (e.g., 7 feet or 9 feet) (see Section 5.1, Strengthening Guardrail).
• 6 inch x 8 inch routed or non-routed wood or composite plastic offset blocks
• Mid-span rail splices
o MGS relocates the splice (weakest link) away from the highest stress point at the post and blockout.
For MGS installations, contractors must use W-beam panels that are 12 feet 6 inches or 25 feet in length, but they may employ a 6-foot 3-inch panel at the end of the run.
Prior to the standard guardrail in Kentucky was the strong-post W-beam. It consists of wood or steel posts that support a W-beam rail element blocked out from the posts. Blockouts are typically made of timber or composite plastic and are 6 or 8 inches deep and 6 inches wide. The strong-post W-beam meets NCHRP 350 Test Level 3 criteria and was mainly used before the adoption of MASH testing criteria. Strong-post W-beam guardrail systems have been installed at different heights, ranging between 27 to 29 inches.
Although the Cabinet has adopted MGS for all new installations, many miles of strong-post W-beam barrier have been installed based on previous NCHRP 350 guidance. Many of these systems have and should continue to have acceptable real-world performance. Raising all existing guardrail systems to meet current criteria is neither cost-effective nor practical. KYTC maintenance crews will continue to maintain strong-post W-beam guardrail systems until they reach the end of their service lives.
Other approved guardrail types may be used on Kentucky highways. Examples of alternative guardrail systems include the weak post W-beam, Weathering Steel Guardrail, and Steel Backed Timber Guardrail. If an alternative guardrail is utilized, it should be appropriate for the road context. Use of an alternative guardrail system requires written justification. The Division a project originates in — Division of Highway Design or Division of Maintenance — is responsible for reviewing and approving the use of alternative guardrail systems.
Contractors that install a temporary guardrail during construction must comply with construction requirements for permanent guardrail.
See the HKP article, Roadside Safety (coming soon), for a discussion of barrier warrants.
The LON is the length of barrier required to adequately shield the object or area of concern and prevent a vehicle from reaching the shielded feature. The length of guardrail must be sufficient to properly shield the object or area of concern, which is critical for roadside safety. See the HKP article, Roadside Safety (coming soon), for a discussion of LON.
During project design, the designer determines whether to install guardrail and calculates the LON. The LON is then used to lay out the guardrail system, and the designer notes on the plans where to install guardrail. If possible, designers should take steps such as flattening slopes with excess earthwork material (where field conditions allow) to reduce the need for guardrail. Refer to KYTC’s Standard Drawings and to AASHTO’s Roadside Design Guide guidance on lateral offsets, barrier deflection, terrain effects, flare rates, and LON.
KYTC measures guardrail quantity in linear feet. The distance is measured along the actual length of the rail between the limits of end treatments, terminal sections and bridge end connections, and crash cushions. Shop curved guardrail is measured in linear feet at 1.3 times the actual length.
Designers commonly design guardrail in to the nearest 12-foot-6-inch or 25-foot increment. A 6-foot-3-inch increment may be used if needed. Field conditions often differ from what plans depict, which can in turn affect the quantity of guardrail needed. Construction Engineers have the final responsibility for determining the placement and installed length of guardrail. A best practice for designers is to slightly overestimate guardrail length so that any construction field adjustments result in a negative-cost change order.
During construction, a guardrail is constructed to the alignment and at the locations shown in the Contract. Sometimes field conditions require that the amount and location of installed guardrail be adjusted. Before ordering guardrail materials, the Engineer and Contractor should meet on the job site to verify the LON and end treatment locations designated in the plans are appropriate for the field conditions. Adjustments should be made as needed. The LON, final location, and end treatment types are approved by the Construction Engineer.
Where possible, construction personnel should flatten earth-fill slopes using excess fill material to attain a clear zone and remove or minimize the need for guardrail. When laying out guardrail field installations, the Engineer should consult with the Roadway Designer when questions arise.
A guardrail installation should have a minimum length of 200 feet (including the end treatments) as this ensures adequate tensile strength for the system to perform well. In some cases, field conditions may warrant a shorter installation, which is acceptable. In these cases, consider strengthening the guardrail (see Section 5.1, Strengthening Guardrail). Similarly, if a guardrail will be installed prior to a fixed object, minimum guardrail length (including end treatments) should be 200 feet. Again, this length may be reduced if field conditions warrant.
Avoid short gaps between two guardrail installations. If connection gaps between barrier termini are less than 200 feet, the installations should be connected as a single run. Installing additional guardrail will be easier to maintain and less expensive than two end treatment installations. Exceptions may be necessary to provide access to locations behind the guardrail (for mowing and other maintenance tasks) or for other project considerations.
Guardrail system performance is tied closely to the height of the W-beam rail element. Installation height is computed by taking a measurement at the center of the rail, at the bolt. Here, the height is measured from either the pavement surface, theoretical pavement, nominal terrain, or gutter pan to the top of the rail. A guardrail should be installed to the true gradient with no sags.
The method used to measure guardrail height varies based on guardrail location. Five scenarios and their corresponding methods are described on the following page.
To give vehicles sufficient opportunity to recover without impacting an obstacle, place guardrail as far away from the traveled way as practical. Typically, guardrail is installed in the shoulder 2 feet from the slope break hinge point (see Section 3.10, Soil Backing). Narrow shoulders are often widened to facilitate guardrail placement.
The usable shoulder is the width available for vehicles to make an emergency stop or parking stop. The graded shoulder is distance from the edge of the travel lane to the normal slope break. Unless guardrail is present, typically the graded shoulder width is equal to the usable shoulder width. Once the usable shoulder width is established for a project and the decision has been made to install guardrail, the graded shoulder will need to be widened 3 feet 5 inches beyond the usable shoulder width to accommodate the guardrail installation. With the guardrail’s face located along the outside of the usable shoulder, the additional graded width provides 2 feet of soil backing behind the guardrail posts. If installing 2 feet of graded shoulder behind the posts is impractical, longer guardrail posts can be utilized.
For a discussion of shoulder width and slope, see the HKP article, Roadway Design Elements (coming soon).
Do not install guardrail posts in structural pavements that will restrict post movement during impact.
In some cases, guardrail may be installed closer to an obstacle rather than at the roadway shoulder edge. Installations of this type reduce the length of rail needed to shield the obstacle. Placing guardrail farther from the roadway lessens the probability of a vehicle impact. At the same time, when a vehicle strikes a guardrail it may have a higher encroachment angle. This is an undesirable condition.
Lateral placement of guardrail away from the shoulder edge is most applicable when small areas of concern are present (e.g., point-type obstacles such as overhead sign bridge supports and bridge piers).
Carefully select where to place guardrail installations on earthen terrain slopes. Judicious positioning will minimize the likelihood of an errant vehicle vaulting over a guardrail and improve the guardrail’s performance. MGS can be placed at any position on a slope (relative to the slope only) if the slope in front of the barrier is flat (i.e., 10:1 or flatter). This also applies to areas in front of the flared section of guardrail and the area approaching terminal ends.
Guardrail should not be placed on a steep slope. For slopes steeper than 10:1, see the HKP article, High-Tension Cable Barrier (coming soon).
While the use of curbs with guardrails is discouraged, curbs more than 6 inches in height should not be used with guardrail. By themselves, curbs typically cannot redirect vehicles, except for very low speed impacts. Placing a curb near guardrail can result in a vehicle vaulting over the barrier. The following guidance can assist in planning curb type and guardrail placement when the use of guardrail/curb combinations is unavoidable:
• For design or posted speeds of 45 mph and less:
o Construct the guardrail so its face is flush with the curb’s face. Avoid locating a curb in front of a guardrail. Consider reducing the curb height to 4 inches and stiffening the rail to reduce vaulting potential. (see Section 5.1, Strengthening Guardrail).
o If it is not practical to install the guardrail flush with the face of the curb, construct the guardrail with a minimum offset of 6 feet from the curb’s face to the guardrail’s face.
• For design or posted speeds greater than 45 mph:
o Facility designs should omit curbs. However, a mountable curb may be used at the edge of the shoulder if necessary. If guardrail is needed in this situation, construct it so the rail’s face is flush with the curb’s face.
Occasionally a guardrail system must be strengthened to reduce the design deflection distance. For example, a transition section is needed where a guardrail attaches to the approach end of a rigid concrete bridge rail (See the HKP article, Barrier Classifications (coming soon)). A guardrail must be stiffened if a rigid object obstacle is present within the design deflection distance. Standard installations can be modified using the following techniques to strengthen the guardrail:
• Add a rubrail
• Install additional posts (reducing the post spacing) (See MGS Working Width Table in Section 3.11.)
• Use extra length posts (e.g., 7-foot or 9-foot posts, not the standard post length of 6 feet)
• Use thicker gauge posts (e.g., 10-gauge posts instead of 12-gauge posts)
• Double nest the rail
• Bolt a W-beam to back of the posts
For extra length posts and nested guardrail, quantities should be measured and bid items provided. Consult Section 719 of the Standard Specifications for Road and Bridge Construction for additional information. Where extra strength is needed different methods may be combined (e.g., when the area of concern is near the back of rail).
A guardrail is classified as a semi-rigid barrier due to its deflection distance upon crash impact (see the HKP article, Roadside Safety (coming soon), for a discussion on barrier categories). A transition section is needed when a guardrail connects to a rigid barrier (e.g., bridge railing or concrete barrier) or rigid object (e.g., bridge pier or sign structure). The transition should provide a gradual, continuous stiffening of the guardrail system from a less rigid to more rigid system. This reduces or prevents a vehicle from snagging or punching through the barrier. Use of a cast-in-place anchor or through-bolt connection is recommended to ensure the connections are as strong as the barrier itself.
Use TL-2 or TL-3 Thrie-Beam Guardrail Transitions to connect W-beam guardrail to concrete bridge rails, rigid barriers, or rigid objects. The TL-2 railing transition should be used when speeds are 45 mph or less. The TL-3 railing transition must be used when speeds are over 45 mph. For more details, see Standard Drawings Nos. BHS-013 and BHS-014.
Historically, the Guardrail Connector to Bridge End Type A was used on both bridge ends on undivided highways and on the approach bridge ends of divided highways. A Guardrail Connector to Bridge End Type A1 was used on the exit bridge ends of divided highways. A Guardrail Connector to Bridge End Type D was applied on each end of a bridge on which a sidewalk was present or its installation was proposed on the structure (and not on the roadway). This only applied to rural structures having two-direction traffic with a sidewalk.
Anda Product Page
Type A, A1, and D connectors are no longer installed on new highway construction. When repairing or restoring existing concrete barrier wall and these guardrail connectors, see Standard Drawings RBC-004, RBC-005, RBC-05N, and RBC-006. Refer to the RBB and RBC series of Standard Drawings in the HKP article, Bridge Railings and Transitions (coming soon), for more details.
On some retrofit projects use of standard guardrail connectors may not be appropriate. Contact Central Office Division of Maintenance for guidance.
Delineators must be installed on new guardrail. Standard Drawing No. RBR-055 (Delineators for Guardrail) illustrates delineator elements, placement, and spacing. Section 830 of the Standard Specifications addresses retroreflective requirements for guardrail delineators.
The District is responsible for deciding (1) whether to install new delineators on existing guardrail systems which lack delineation or (2) whether it is necessary to replace existing guardrail delineation due to non-reflective and/or missing delineators. High-priority locations for guardrail delineation include curves and ramps on freeways and expressways, as well as guardrail sections located in the median. The District may elect to place delineation to indicate openings at entrances on highways.
Where a guardrail end treatment adjacent to the roadway is marked, a Type 3 object marker is typically used. Alternating stripes of Type 3 object markers should slope downward, toward the side on which traffic is to pass. Generally, the end treatment manufacturer supplies Type 3 object markers. Use retroreflective sheeting that conforms to the size of the approach end.
Double-faced guardrail has two W-beam rails configured as a single beam on each side of post. It is typically used in the median in place of concrete barriers, particularly when the required shielding length is relatively short. Double-faced guardrail is also used when a guardrail may be exposed to impacts from either side. When installed near the pavement edge, it is critical for the area between the posts to be free of asphalt.
On longitudinal guardrail installations, double blockouts (up to 16 inches deep) may be used to increase the post offset to avoid obstacles such as curbs. There is no limit on the number of posts that can have double blockouts installed.
Do not employ double blockouts for transitions and terminals, unless approved by the manufacturer. Under special circumstances (e.g., avoiding buried obstacles that are not relocated), additional blockouts may be installed to obtain up to 24 inches of clearance (three 8-inch blockouts or two 12-inch blockouts) for one or two posts in a section of guardrail. Standard Drawing RBR-031 (Guardrail End Treatment Type 3 Pipe Drainage Detail) offers an example of using extra blockouts.
Omit a post only under special circumstances and only on a standard run of guardrail. Omitting a post requires the construction engineer’s approval.
Single posts may be omitted along runs of MGS W-beam guardrail without the system needing modification (i.e., no weakened posts, no nested rail elements, no special posts). Always consider the following issues before taking this step:
1. At least 50 feet is required between omitted posts, a terminal, or other special design.
2. Omitted posts cannot be used within transitions, terminals, or special designs.
3. No curbs are present where guardrails are installed.
4. Additional deflection resulting from the omitted post.
Occasionally, an intersecting side road or driveway is located so close to a side obstacle that installing a minimum length MASH TL-3 guardrail is infeasible. This most occurs often at bridge ends. A short radius curved guardrail installation may accommodate this situation. See Standard Drawing RBI-001 for more details.
Keep the following in mind when designing a short-radius curved guardrail:
• Installations at intersections and driveways can create nuisance hit problems for turning traffic (e.g., tractor trailers turning off of or onto side roads, farm implements turning into and out of field entrances). Check turning patterns to ensure a guardrail installation will not significantly affect turning movements.
• Installations at intersections and driveways can obstruct motorist sight, especially if the side road or entrance is at or near the crest of a vertical curve. Perform sight distance analysis for both plan and profile views to determine what effects guardrail installation may have on motorist line-of-sight.
On roadways where the design speed is between 30 and 45 mph and there is a curb adjacent to the traveled way (e.g., urban and suburban roadways), keep the border area free of obstacles. Any decision to use a guardrail within the border area should be informed by careful evaluation. A guardrail used in the border area should present less of a hazard than the obstacle it shields. See Chapter 10 of AASHTO’s Roadside Design Guide for further guidance on clear zones in urban areas.
Use the appropriate omitted-post design (as discussed above) if rock is present where a single guardrail post is to be installed. If rock is present at several points where posts will be installed, place the posts in cored holes (see Section 719.03.01 of the Standard Specifications for Road and Bridge Construction).
When shales are used in embankment fill sections, acidic shale is generally encased inside the embankment. At least 4 feet of nondurable shale or clay soil should be placed atop the embankment to control the corrosion of guardrail posts. It may be appropriate to install corrosion-resistant guardrail posts. See Special Note 8N Corrosion Resistant Guardrail and the Geotechnical Guidance Manual GT-609-5 on Acid-Producing Shales.
Horizontal lagging walls are often used for temporary or permanent retention of soil material and other backfill. Lagging may consist of wood, guardrail, or geogrid. When backfill is placed or compacted behind the guardrail wall, it is imperative that rails not to be damaged.
Lagging has traditionally been designed based on experience or empirical methods. (e.g., the Federal Highway Administration uses the Goldberg Zoino chart). Contact the Geotechnical Branch for more information.
As the leading resource on fall protection, we at Diversified Fall Protection are frequently asked for help understanding and complying with OSHA requirements for guardrail and safety railing systems.
Below, we’ll explain OSHA’s official rules on guardrail for general industry applications and show you how your business can remain compliant with these regulations.
For more help, contact the team of experts at Diversified Fall Protection. Our engineers will design and implement a complete, OSHA-compliant guardrail system to protect your team when working on rooftops and other elevated surfaces.
OSHA requires guardrails on any walking-working surface that is 4 feet or more above a lower level. Additionally, stairways with 4 or more steps must have a stair rail system with a handrail. If employees are working near dangerous equipment, guardrails are required at any height to prevent falls.
A guardrail, or guard rail, is a stationary, fixed fall protection system designed to prevent workers from stepping over the edge of a walking-working surface. OSHA .29(b) is the portion of the regulations that contains system requirements that employers must follow to ensure guardrail systems will protect workers from falling to lower levels.
There are three main parts of a guardrail: The top rails, the midrails, and the vertical posts. Each part of the guardrail must comply with OSHA’s rules, including material type, size, height, and location. We explain each of these below.
Above the OSHA Figure D-11 diagrams illustrating guardrail heights and gap requirements:
42-inch (+/- 3 inches) top rail or 107cm (+/- 8 cm)
Midrail halfway between top rail and working surface
Vertical balusters spaced no more than 19 inches (48 cm) apart
Diversified Fall Protection provides turnkey guardrail systems that comply with all of the following OSHA requirements for guard rail.
According to OSHA, top rails (or equivalent guardrail system members) must be 42 inches (107 cm), plus or minus 3 inches (8 cm), above the walking-working surface. The top edge height may exceed 45 inches (114 cm), as long as the guardrail system meets all other criteria.
Guardrail is required for any platform 4 feet or higher above a lower floor or the ground. Guardrails are required have vertical heights of 42 inches from the upper surface of the top rail to floor, platform, runway, or ramp level.
If there is not a wall or parapet at least 21 inches (53 cm) high, then midrails must be installed halfway between the top edge of the guardrail and the walking-working surface. Screens, mesh, intermediate vertical members, solid panels, or other equivalents can be considered “midrails” for this purpose.
If screens and mesh are used, they must extend from the walking-working surface to the top rail and along the entire opening between top rail supports.
Intermediate vertical members (such as balusters) must be installed no more than 19 inches (48 cm) apart. Other equivalent intermediate members (such as additional midrails and architectural panels) should be installed so that the openings are not more than 19 inches (48 cm) wide.
OSHA requires guardrail be strong enough to withstand force both outward and downward along the top rail and at the midrail section.
Guardrail systems need to be capable of withstanding a force of at least 200 pounds (890 N) at any point along the top rail. This force is applied in a downward or outward direction within 2 inches (5 cm) of the top edge. When tested in a downward direction, the top rail of the guardrail system must remain at least 39 inches (99 cm) above the walking-working surface.
Midrails, screens, mesh, solid panels, and other equivalent intermediate members must be capable of withstanding, without failure, a force of at least 150 pounds (667 N) applied in any downward or outward direction at any point along the intermediate member.
Guardrail systems need to be smooth-surfaced. This is to protect employees from injury, such as punctures or lacerations, and to prevent catching or snagging of clothing. Our railings have a powder-coated finish to meet this requirement.
OSHA also requires that the ends of top rails and midrails do not overhang the terminal posts, which are the posts at each end. The only exception is if the overhang does not pose a projection hazard.
Similarly, steel and plastic banding are not permitted to be used for top rails or midrails, and guard rails must be at least 0.25-inches (0.6 cm) in diameter or in thickness. These requirements also protect workers from injury caused by too much force applied at these points.
OSHA says that when guardrail systems are used at hoist areas, there needs to be a removable guardrail section placed across the access opening when employees are not performing hoisting operations. This section must have a top rail and midrail. You may use chains or gates instead of a removable guardrail section if you show they provide the same level of protection as guard rails.
Guardrail systems used around holes must be installed on all unprotected sides or edges of the hole. If materials will be passed through the hole, no more than two sides of the guardrail system can be removed at a time. When materials are not being passed through the hole, the hole must be guarded by a guardrail system along all unprotected sides or edges or closed over with a cover.
When used around holes that serve as points of access (such as ladderways), the guardrail system opening needs to have a self-closing gate that slides or swings away from the hole. The gate must have a top rail and midrail (or equivalent intermediate member) that meets the requirements for guardrail above. The other option is to offset it to prevent an employee from walking or falling into the hole.
For ramps and runways, guard rail must be installed along each unprotected side or edge. You can use Manila or synthetic rope for top rails or midrails if it is inspected as necessary to ensure that the rope continues to meet OSHA strength requirements described above (the 200-pound and 150-pound tests).
If you are looking for more details, kindly visit Highway Guardrail Posts.