So to clear things up the load is the "circuit", right? So if that's the case then let's walk through this. So I'm building a Joachim Gerhard Buffer for an upcoming ES DAC project. The buffer requires a power supply that can provide +/-15v and 25mA per channel for a total of 50mA. So my supply or in this case SSLV1.1 needs to provide at least 25mA and +/-15v per regulator. So from my reading it appears the SSLV is pretty customizable with a few adjustments to get what you want. The challenge is finding the parts needed to get there, which should probably be saved for a more appropriate thread. The transformer then has to meet the needs of the regulator in order to perform well.Yes, first of all "load" is just whatever you're sending power into. For a power supply, it's the circuit to be supplied, for an audio amp it is a speaker, etc. For a stage within the audio amp you could say it's the following stage, so it is kind of a "referenced to what" concept and I should have been more clear.
Got it. So basically a 15VA transformer is using 15 watts of power per hour - or maybe not.No. It can output 15VA (watts) continuously.
So in the case of the SSLV it looks like I'd need more like 2x20VA because of voltage drop across the regulator(s). So another question I have is based around current needs.15VAC@25mA is only 0.375VA (x2=0.750VA). 15VDC@100mA is only 1.5 watts (x2=3W). I can't see you needing a transformer over 10VA total. Current draw always depends on the load, not the supply. Admittedly, I didn't view the transformer submissions, nor am I certain of your application. For specifics, a separate project thread may be a better place.
I'll have to take a closer look. I think it's time to read Electronics for Dummies because of a lot of this is getting way beyond painting by numbers -- which I don't mind of course. I love how this hobby always provides a challenge.It's past that time.???? There is a good web page describing all the steps. I've linked to it before, but I couldn't find the link or the page or a saved doc. I do have a good article by Steve Ciarcia that I'd be willing to to you. It's a >200W single-output linear supply project but the design can be scaled bigger or smaller - it's his thorough description of design choices that's valuable.
Figure 1: Transformer
You can find more information on our web, so please take a look.
A transformer is a passive electrical device that uses electromagnetic induction to transfer electrical energy from one circuit to another. Selecting the proper transformer for an application requires careful consideration of several factors, such as voltage, current, type of load, efficiency, environment, and cost. This article gives a step-by-step guide on choosing a transformer and analyzing various powers in a transformer.
Read our overview article on transformers for more information on how they work, their construction, and their types. Transformers are available in multiple designs, specifications, and sizes. It is important to consider the following:
Note: The voltage and frequency of the main power supply vary from one country to the other. Countries like the USA use the main power supply of 120 volts operating at 60 Hz, whereas those in Europe like the UK, Netherlands, and Germany operate at 230 volts and 50 Hz. Choose the transformer accordingly. See the complete list of countries with their corresponding mains power supply voltage and operating frequencies for more details.
Figure 2: Step-down (left) and step-up (right)
Note: Generally, the primary and secondary voltages are listed in the transformer specifications. But in exceptional cases like a current transformer, the primary and secondary currents are listed instead.
The rated load (apparent power) of a transformer is measured by VA (Volt-Ampere). The rated power represents the total amount of power the transformer can deliver to the load. To calculate the rated load needed:
Note: Small transformers rate their deliverable power in volt-amperes, but much larger power transformers are rated in units of Kilo volt-amperes (kVA), and Mega volt-amperes (MVA). Therefore, VA, kVA, and MVA are similar units. For example, 6 VA is equal to 0.006 kVA.
Read our articles on single-phase and three-phase transformers for more information on their working and design.
Transformer load capacity is the maximum amount of electrical power that a transformer can safely and efficiently handle without overheating or causing damage. For example, a transformer with a 200 VA rating can handle 200 volts at one ampere of current or 100 volts at two amperes of current.
Knowing the VA value of the transformer, it is possible to determine the current across the load by rearranging the equation for VA.
Note: Loading a transformer above 80% of its VA rating is not recommended. After calculating the VA, divide the value by 0.8 to get the minimum VA rating needed. An electrician or electrical engineer should review and confirm all values for safety reasons.
Calculate the rated power of a single-phase transformer with a load voltage of 24 volts and a maximum load phase current of 5 amperes.
The VA rating of the transformer = (V × I)= (24 × 5) = 120 VA
Dividing the VA by 0.8, the revised VA = 150
If you want to learn more, please visit our website Tianya.
Choose a transformer with a VA rating of approximately 150 for the load.
The efficiency of a transformer is given by:
When dealing with transformers, the primary power is generally referred to as volt-amps (VA) to distinguish it from the secondary power. Therefore, the efficiency is given by:
Transformers have high efficiencies due to the absence of moving parts. Transformers are also called static AC machines. The efficiency of a well-designed power transformer is very high, averaging over 98 percent. The only losses are due to core losses, maintaining the alternating magnetic field, resistance losses in the coils, and power used for cooling.
In an AC circuit, the power factor is the cosine of the phase difference between voltage and current. The power factor represents the fraction of the rated power (apparent power) that is consumed (true power) by a circuit.
A low power factor means that a higher current is required to deliver a given amount of real power to the load, which results in higher energy losses and reduced efficiency. The power factor can also help calculate the total power that the transformer can handle without overloading.
The apparent power, real power, and active power can be represented in a right-angle triangle known as the power triangle (Figure 3).
Figure 3: Power triangle showing active power (P), apparent power(S), and reactive power (Q) in a magnetic circuit.
Use Figure 3 to derive the relation between various types of power in a transformer.
There are multiple sources of power losses in a transformer.
The various losses in a transformer can cause the device to overheat, leading to damage and a shorter transformer lifespan. It is necessary to reduce these losses to improve transformer efficiency and ensure the optimal performance of the electrical system. Common measures are:
To size a transformer, determine the load requirements of the electrical system in terms of voltage and current, and then select a transformer with a suitable kVA rating based on the load requirements.
To calculate the VA (Volt-Ampere) rating of a transformer, you need to calculate the product of the voltage and current ratings of the transformer.
The standard kVA sizes for single-phase transformers are: 1, 1.5, 2, 3, 5, 7.5, 10, 15, 25, 37.5, 50, 75, 100, 167, 200, 250, and 333 (KVA)
The efficiency of a transformer is less than 100% due to the various types of losses within the device, like core loss, copper loss, and dielectric loss.
For more Power Supply Transformerinformation, please contact us. We will provide professional answers.